Inverter Battery Backup Calculator

How long your inverter battery will last on your load

Battery and Load

Ah
V

E.g. 3 fans (75 W each) + 4 LED bulbs (9 W) + Wi-Fi (10 W) ≈ 270 W

W
%
hours

Your Backup Time

4 h 5 minBackup
1,224 WhUsable energy
1,800 Wh
Total battery energy
147 Ah per battery
Ah needed for 4 h

Backup at different loads

LoadBackup
100 W12 h 14 min
200 W6 h 7 min
300 W4 h 5 min
500 W2 h 27 min
750 W1 h 38 min
1000 W1 h 13 min
Read the guide · 5 minHow Long Will My Inverter Battery Last? Backup Time ExplainedRead the guide · 6 minPM Surya Ghar Solar Subsidy: How Much You Get and How to Apply
  1. 1
    Enter your battery
    Ah, voltage and how many
  2. 2
    Add your load
    Watts of everything on the inverter
  3. 3
    See the backup time
    Or the Ah you need

How is inverter backup time calculated?

Backup is the battery's usable energy divided by the load, after the inverter's own losses. You shouldn't fully drain a battery, so only part of its capacity counts.

Backup (hours) = Ah × V × batteries × usable share × efficiency ÷ load (W)

Battery Ah needed = hours × load ÷ (V × batteries × usable share × efficiency)

Add up your load

Typical wattages: ceiling fan 50–75 W (BLDC fans about 30 W), LED bulb 9–12 W, LED TV 60–100 W, Wi-Fi router 10 W, laptop 50 W, fridge 100–200 W running. Avoid running irons, geysers, ACs or pumps on a home inverter.

Battery life

Lead-acid and tubular batteries last longer if they aren't drained below about 20%. Top up distilled water in flooded tubular batteries every 2–3 months, and keep them in a ventilated place.

Related calculators

Frequently asked questions

How long will a 150Ah battery last?

On a 300 W load, about 4 hours (150 × 12 × 0.8 × 0.85 ÷ 300). On 100 W, about 12 hours.

Why is my backup less than calculated?

Older batteries lose capacity, and heavy loads drain lead-acid batteries less efficiently. Inverter idle consumption and loose connections also cut backup.

Which inverter rating do I need?

Add up the load in watts and choose an inverter whose VA rating is about 1.25–1.5 times that. A 300 W load suits a 600–900 VA inverter.